Eleanor Schofield – Mary Rose Portsmouth
ML4106 data logger
Eleanor Schofield, Head of Conservation and Collections Care, The Mary Rose Trust
Part of the Hanwell Pro HL4000RHT Series, the HL4106 data logger is a combined temperature and humidity unit fitted with on-board sensors.
Temperature ranges between -20°C to +60°C. Humidity 10-90%RH non-condensing.
Part of the Hanwell Pro HL4000RHT Series, the HL4111 RH/T data logger measures a single channel using a high accuracy RH/T probe.
Instrument measuring range: -50°C to +100°C | 0-100% RH
Probes are available separately – see below for compatible probes
Part of the HL4000RHT range, the HL4115 RH/T data logger has LCD display and two channels for external temperature and RH sensors.
Instrument measuring range: -40°C to +60°C | Humidity measuring range: 0-100%RH non-condensing with external probes
The ML4106 data logger is our best seller for temperatures and humidity monitoring with onboard RH/T sensor.
Temperature ranges between -20°C to +60°C. Humidity 0-100%RH
Part of the Hanwell Pro ML4000RHT Series, the ML4106 RH/T radio transmitter is our best selling unit fitted with onboard sensors.
Temperature range -20°C to +60°C, Humidity range 0-100%RH non-condensing
Part of the Hanwell Pro ML4000RHT Series, the ML4108 RH/T radio transmitter has fitted onboard RHT sensor and optional remote surface temperature probe.
Instrument temperature measuring range: -20°C to +60°C which is extended to 0°C to +125°C with external probes | Humidity range: 10-90%RH non-condensing
External Probes are available separately – see below for compatible probes
The ML4108 data logger is a three channel temperature and humidity logger with optional remote surface temperature probe.
Part of the Hanwell Pro ML4000RHT Series, the ML4114 temperature and humidity data logger measures a single channel using a high accuracy RH/T probe.
Instrument measuring range: -40°C to +60°C with external probe
Part of the Hanwell Pro RL4000RHT Series, the RL4109 RH/T radio transmitter is fitted with onboard sensors and optional remote surface temperature probe.
Temperature ranges between -40°C to +80°C. (Probes sold separately)
Part of the Hanwell Pro RL4000RHT Series, the RL4111 and RL4112 RH/T radio transmitters use high accuracy RH/T probes.
Instrument measuring range:
RL4111 – Range -40°C to +60°C RL4112 – Range -50°C to +100°C
0-100% RH
Part of the Hanwell Pro RL4000 RHT series, The RL4116 RH/T radio transmitter with C-Sense temperature and RH probes.
Receive the latest updates, offers and more by signing up to the Hanwell mailing list.
We’ll never share your email and you can opt out at any time.